Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Rouibah, Abdelkader"

Filter results by typing the first few letters
Now showing 1 - 4 of 4
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Evaluation des performances des tours solaires
    (2020) Rouibah, Abdelkader
    L'augmentation de la production d'énergie solaire est devenue une solution pour répondre à la demande en électricité et réduire l'effet de serre dans le monde entier. Cette thèse a pour objectif de déterminer les performances et la viabilité de l'irradiation normale directe du projet de trois centrales solaires à tour en Algérie, qui seront programmées à installer dans les hauts plateaux et dans le Sahara (régions de Béchar, El Oued et Djelfa). La performance des centrales a été obtenue par un simulateur SAM (Model System Advisor).Il utilise des données réelles et satellitaires recueillies à partir des fichiers météorologiques appropriés. On a observé une relation entre le multiple solaire (SM), la production d'électricité et les heures du stockage d'énergie thermique (TES). Les résultats ont montré que le champ optimal d’héliostat correspond à SM=1,8 et TES=2 en Béchar, SM=1,2 et TES=2 pour El Oued, et SM=1,5 et TES=4 pour Djelfa. Cette étude a montré qu'il existe une relation intéressante entre le multiple solaire, la production d'électricité et la capacité de stockage
  • No Thumbnail Available
    Item
    Évaluation dynamique des risques majeurs dans les installations pétrochimiques
    (2012) Rouibah, Abdelkader
    Nous traitons dans ce mémoire l'évaluation des risques industriels majeurs dans les installations pétrochimiques. Cette étude se compose de quatre parties importantes: La première partie comporte l'analyse des différentes méthodes et approches utilisées dans la fiabilité pour évaluer les risques industriels, ainsi que l'importance de chaque approche et méthode avec leur avantages et inconvénients. La deuxième partie est consacrée à la théorie de dynamique des stimuli TSD qui utilise un type spécifique de chemins et séquences pour résoudre les équations de la théorie de dynamique probabiliste basée sur les stimuli SDTPD. Comme on présente aussi l'algorithme de recherche adaptatif pour l'échantillonnage par maillage des chemins de dommage dans les séquences, et nous précisons son avantage par rapport à la méthode de Monte Carlo. La troisième partie est réservée pour l'analyse thermo hydraulique du réservoir E610 de l'usine de Bhopal, dans laquelle on étudie l'évolution des différentes variables physiques dans le temps telles que la pression, la température et les concentrations molaires du mélange formé dans le réservoir de stockage de MIC. La quatrième partie est consacrée à la simulation de la dynamique multi-variable des réactions exothermiques de mélange gazeux, on prend le scénario de l'accident de Bhopal et par l'application de l'algorithme de recherche adaptatif, on a pu simuler les séquences accidentelles avec le calcul des fréquences d'excès du domaine de dommage
  • No Thumbnail Available
    Item
    The Impact of Direct Normal Irradiation on the Solar Tower Power Plant Performance based on Real and Satellite Data: Analysis on Algerian Regions
    (EBSCO, 2020) Rouibah, Abdelkader; BENAZZOUZ, Djamel; KOUZOU, Ahmed Lakhdar; HAFAIFA, Ahmed
    The present paper presents a deep study on the possibility of implementing Concentrated Solar Power (CSP) plants in Algeria for the production of the electrical energy. Indeed, this paper focusses mainly on the main parameters, which can have an important impact on the choice of the location, the dimension and the available thermal energy storage system. In this study, three main parameters are investigate such as the solar Multiple (SM), the thermal energy Storage (TES) capacity and the Capacity Factor (CF),where the main challenge is to find their optimal values based on the available solar energy deposit and the different constraints of the four considered region of Algeria presented in this paper. These optimal values will be used in the implementation and the management of the considered CSP to ensure the maximal probability of the location in terms of balance between the production and the demand of energy. This paper benefits from the onsite real data and the satellite data for finding the optimal values of the aforementioned parameters, where it has been proved that the satellite data can ensure more precise profitability of the available solar energy to ensure more produced electrical power. The obtained results allow to obtain optimized configuration of the implemented CSP and demonstrate that the use of such solar power plant can be of great interest to ensure more times production of the national electrical energy demand, especially in the large Sahar of Algeria which can power several part of the world and neighbour countries. Copyright of Electrotehnica, Electronica, Automatica is the property of ICPE SA (Editura Electra) and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract
  • No Thumbnail Available
    Item
    Solar Tower Power Plants of Molten Salt External Receivers in Algeria: Analysis of Direct Normal Irradiation on Performance
    (MDPI AG, 2018) Rouibah, Abdelkader; Benazzouz, Djamel; Rahmani, Kouider; Al-Kassir, Awf; Calcedo, Justo García-Sanz-; Maghzili, k.
    The increase of solar energy production has become a solution to meet the demand of electricity and reduce the greenhouse effect worldwide. This paper aims to determine the performance and viability of direct normal irradiation of three solar tower power plants in Algeria, to be installed in the highlands and the Sahara (Béchar, El Oued, and Djelfa regions). The performance of the plants was obtained through a system advisor model simulator. It used real data gathered from appropriate meteorological files. A relationship between the solar multiple (SM), power generation, and thermal energy storage (TES) hours was observed. The results showed that the optimal heliostat field corresponds to 1.8 SM and 2 TES hours in Béchar, 1.2 SM and 2 TES hours for El Oued, and 1.5 SM and 4 TES hours for Djelfa. This study shows that there is an interesting relationship between the solar multiple, power generation, and storage capacity. © 2018 by the authors.

DSpace software copyright © 2002-2026 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify