Experimentation of practical new technique for single and two simultaneous diodes open faults automatic detection and localization in six diodes three phase bridge rectifier
No Thumbnail Available
Date
2008
Authors
Benslimane, T.
Journal Title
Journal ISSN
Volume Title
Publisher
SAE International
Abstract
The faulty performance of six diodes three phase rectifier is studied under one and two simultaneous open-diodes conditions. This rectifier is feeding a resistive load. The rectifier three phases currents zero harmonic components and their maximum and minimum values are used as diagnostic indices. A knowledge algorithm is based to get information on which diode is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switches. Presented simulation results confirm the effectiveness of the proposed methodology.
Description
Keywords
Automatic Detection, Diagnostic indices, Fault conditions, Faulty switches, Harmonic components, Minimum value, Open faults, Resistive loads, Three phasis, Three-phase bridge rectifier, Three-phase rectifiers, Algorithms, Bridge circuits, Diodes
Citation
2008 World Congress; Detroit, MI; United States; 14 April 2008 through 17 April 2008; Code 85694