Currents mean and min/max values for diagnostic of one and two simultaneous open-switches faults in three phase voltage inverter fed permanent magnet brushless DC motor drives

No Thumbnail Available

Date

2008

Journal Title

Journal ISSN

Volume Title

Publisher

SAE International

Abstract

The faulty performance of permanent-magnet (PM) brushless dc motor drives is studied under one and two simultaneous open-switches faults conditions. This DC motor is supplied with three phase two level six IGBT (Insulated-Gate Bipolar Transistor) voltage source inverter. The three phases currents mean, min and max values of the DC motor are used as diagnostic indices. A knowledge algorithm is based to get information on which IGBT is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switch. Presented simulation results confirm the effectiveness of the proposed methodology

Description

Keywords

Brushless dc motor drives, Diagnostic indices, Fault conditions, Faulty switches, Permanent magnet brushless DC motor, Three phase, Three phase voltage inverter, Three phasis, Voltage source inverter, Algorithms, Brushless DC motors, Insulated gate bipolar transistors (IGBT), Electric drives

Citation

Endorsement

Review

Supplemented By

Referenced By