Classification of the systems used in surface electromyographic signal detection according to the degree of isotropy

dc.contributor.authorMessaoudi, Noureddine
dc.contributor.authorBekk, Raïs El’hadi
dc.contributor.authorBelkacem, Samia
dc.date.accessioned2018-11-25T08:17:55Z
dc.date.available2018-11-25T08:17:55Z
dc.date.issued2018
dc.description.abstractSurface electromyographic (EMG) signals are known to be strongly influenced by anatomical, physiological and detection system parameters. Among the detection system parameters, we are interested in the effect of muscle fiber inclination on the electrode arrangement. The purpose of this study was to determine the best and the worst orientation of the electrodes arranged in nine detection systems relative to the muscle fiber direction and also to classify the investigated systems according to their degree of isotropy. The study was based on simulated surface EMG (sEMG) signals generated in a cylindrical multilayer volume conductor. The orientation of electrodes with respect to the fiber direction was defined by the fiber inclination angle (FIA). For each detection system, the mean power (MP) of the simulated signals was computed at different FIAs and used as a basis for evaluating the effect of muscle fiber inclination. We showed that for the FIA range of 0–180°, approximately isotropic systems had three positions to record sEMG signals under good conditions (MP was maximum). However, longitudinal and transversal highly anisotropic systems had two and one positions, respectively, at which sEMG signals were detected under good conditions. We showed also that the degree of isotropy of the nine detection systems investigated was less affected by the increase in muscle and fat thicknesses. However, with an increase in inter-electrode distance (IED), the degree of isotropy of approximately isotropic systems decreased while the degree of isotropy of highly anisotropic systems increaseden_US
dc.identifier.issn2187-5219
dc.identifier.urihttps://dspace.univ-boumerdes.dz/handle/123456789/5280
dc.language.isoenen_US
dc.publisherJ-STAGEen_US
dc.relation.ispartofseriesAdvanced Biomedical Engineering, Volume 7 (2018);PP.107-116
dc.subjectAnisotropyen_US
dc.subjectDetection systemen_US
dc.subjectElectrodesen_US
dc.subjectElectromyographyen_US
dc.subjectInclinationen_US
dc.titleClassification of the systems used in surface electromyographic signal detection according to the degree of isotropyen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
noureddine messaoudi.pdf
Size:
167.56 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: