A new technique for simultaneous detection of one to two open-switch faults in three phase voltage-inverter-fed PM brushless DC motor drive
| dc.contributor.author | Benslimane, T. | |
| dc.date.accessioned | 2015-04-22T10:13:24Z | |
| dc.date.available | 2015-04-22T10:13:24Z | |
| dc.date.issued | 2008 | |
| dc.description.abstract | The faulty performance of permanent-magnet (PM) brushless dc motor drives is studied under one and simultaneous two open-switches faults conditions. This DC motor is supplied with a three phase two level six IGBT voltage source inverter. The three phases currents mean values of the DC motor are used as diagnostic indices. A knowledge algorithm is based to get information on which IGBT is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switch. Presented simulation results confirm the effectiveness of the proposed methodology | en_US |
| dc.identifier.uri | https://dspace.univ-boumerdes.dz/jspui/handle/123456789/477 | |
| dc.language.iso | en | en_US |
| dc.relation.ispartofseries | International Journal of Electrical, Computer, and Systems Engineering/ Vol.59, N°2 (2008);pp. 97-100 | |
| dc.subject | Brushless dc motors | en_US |
| dc.subject | Fault diagnosis | en_US |
| dc.subject | IGBT | en_US |
| dc.subject | One open-switch | en_US |
| dc.subject | Two open- switches | en_US |
| dc.subject | Mean value | en_US |
| dc.subject | Min and max value | en_US |
| dc.subject | Logic functions | en_US |
| dc.subject | Boolean value | en_US |
| dc.title | A new technique for simultaneous detection of one to two open-switch faults in three phase voltage-inverter-fed PM brushless DC motor drive | en_US |